DESIGN AND CONSTRUCTION OF A REFRIGERATING UNIT
ABSTRACT

            The design and construction of s refrigerating unit is handled from the knowledge of the working principles of laws of thermodynamics.
            The size of the containing vessel i.e the case as established to be of 45cm by 32 cm in dimension. The Angle iron mild steel to used in the fabrication and welding. The box case of two layers are fabricated. Plastic (cooler) box is then  placed inside the upper part with the other parts of the refrigerator were brought in. they were all fixed onto a wooden base with all the connections (electrical) made.
            The capacity of the refrigerator is based on the workdone by the compressor which is O.I hp in specification. The size of the components used are
i.                    Condenser: The size is 0.1hp and it is a plate type condenser with extended surface.
ii.                  Compressor: The size is 0.1hp (75 watts)
iii.                Copper wire: it is of 0.5cm in diameter and the total copper wire length is about 600cm (1½ roll)
The introduction of cooling fluid and filling of the compressor enabled the compressor to start functioning when connected to electricity using a 13 AMP rated socket
            The interior of the plastic box is lined with dominium box with tubes arranged in convolution around it. This world effectively and cooled the water dropped into it. It compares favorably with the ones in the market.
TABLE OF CONTENT
CHAPTER ONE
1.0              INTRODUCTION
1.1       SCOPE OF THE PROJECT
CHAPTER TWO
HISTORY OF REFRIGERATION
TYPES OF REFRIGERATING DEVICE
USES OF REFRIGERATION
CHAPTER THREE
SEQUENCE OF OPERATIONS
SELECTION OF REFRIGRANTS
CONSTRUCTION PROCEDURE
ECONOMIC ANALYSIS
CHAPTER FOUR
4.1              CONCLUSION
4.2              RECOMMENDATIONS
REFERENCES.
CHAPTER ONE
1.0       INTRODUCTION
            Refrigeration is the process of lowering the temperature of a substance below that of its surrounding.
            Refrigeration is the practical application of the first and second law thermodynamics. Comprehensive understanding of the basic principles of thermodynamics is crucial for full understanding of basic operation of refrigerator. The first law states that the energy can neither be created nor destroyed. If energy of 2.5J appears in one forms it appears in another without a corresponding decrease of energy on the other form. The second law states that no system can receive heat at a given temperature and reject it at a higher temperature without receiving work from the surrounding heat always flow from Warner to cooler body. Through consideration of these laws, the ideal refrigeration cycle are considered. The carnot cycle is reversible and consist of adiabatic compression witherma rejection of heat, adiabatic expansion and wothermal addition of heatl the carnot cycle is unattainable ideal which serves as a standard of comparison and it provides a convenient guide to the temperature that should be maintained to achieved effectiveness. The efficiency or coefficient of performance (C.O.P.) of a carnot cycle depends on the temperature at which heat is added and rejected.
            Therefore,
            C.O.P =           T1
                                    T2 – T1
 Where T1 = Evaporation temperature
            T2 = Conducting temperature
In actual refrigeration there will be issues causing C.O.P to be less than that for ideal cycle. The basic methods of refrigeration like the mechanical refrigeration ejector (steam jet) refrigeration absorption refrigeration uses similar process for obtaining refrigeration effect. That is evaporation in the evaporator, condensation in the condenser, the main difference is in the way used refrigeration being done. The most compression. The cycle efficiency can be ignored in a number of ways.
1.       Multistage system: When evaporation and condensing temperature (pressure) difference is large, it is prudent to separate compression into two stages. The use of multistage system open up the opportunity to use flash gas removal and inter cooling as a measure to improve performance of the system
2.       Cascade system: This appears in situation where the evaporating temperature is very low (below 600c). the refrigerant is used to achieve the cooling. The liquid with low boiling points are used as refrigerants.
1.1       SCOPE OFD THE PROJECT
            The scope of this project is mainly concerned with the design and construction of a refrigerating unit that has a very performance level and with the cost of fabrication lower than that of existing prototype
            A good refrigerator is one that has all the basic components of compressor, condensers, fan motor, copper tubes and other. This project must apply all the principles of refrigeration.
  
DESIGN AND CONSTRUCTION OF A REFRIGERATING UNIT
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Chemical Engineering
  • Project ID: CNG0001
  • Access Fee: ₦5,000 ($14)
  • Chapters: 4 Chapters
  • Pages: 22 Pages
  • Methodology: nil
  • Reference: YES
  • Format: Microsoft Word
  • Views: 2.3K
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Chemical Engineering
    Project ID CNG0001
    Fee ₦5,000 ($14)
    Chapters 4 Chapters
    No of Pages 22 Pages
    Methodology nil
    Reference YES
    Format Microsoft Word

    Related Works

    ABSTRACT This work deals extensively with the design and construction of an electronic dice display (EOD) with audio unit. The device displays the of a hudo dice in numberical form and also produces sound as it displays the number. The device works with principle of chance... Continue Reading
    ABSTRACT Burglar alarm circuit is made up of five major sections. The power supply section; it connects to the source of power, the trigger section which produces trigger current, touch section that controls the supply of power in the circuit, alarm section that sounds when current... Continue Reading
    ABSTRACT This work deals extensively with the design and construction of an electrodice display (EOD) with audio unit. The device displays the value of a ludo dice in numerical form and also produces sound as it displays the number. The device works with principle of chance... Continue Reading
    This work deals extensively with the design and construction of an electrodice display (EOD) with audio unit. The device displays the value of a ludo dice in numerical form and also produces sound as it displays the number. The device works with principle of chance employed by ludo game players. The output of the display is usually very rapid that... Continue Reading
    . ABSTRACT This work deals extensively with the design and construction of an electronic dice display (EOD) with audio unit. The device displays the of a hudo dice in numberical form and also produces sound as it displays the number. The device works with principle of chance... Continue Reading
    This work deals extensively with the design and construction of an electrodice display (EOD) with audio unit. The device displays the value of a ludo dice in numerical form and also produces sound as it displays the number. The device works with principle of chance employed by ludo game players. The output of the display is usually very rapid that... Continue Reading
    ABSTRACT The project of construction is one (1) horse power Air conditioning unit which was executed successfully. With up to seventy five percent (75%) efficient performance. The project started with the construction of the size of the air conditioning unit. The air conditioning unit is 60x40x 45cm in... Continue Reading
    ABSTRACT Distillation unit is the judgment used for the separation of liquid mixture depending on the volatility of the component. It has the top section and bottom section. In the top section this is where more volatile component goes and the bottom section is where the divider or less volatile component... Continue Reading
    ABSTRACT A table top liquid-liquid extraction unit was constructed. The project also involved the repair and servicing of peristaltic suction pump, by painting it, replacing the connecting cord to the power supply, refilling of the work out suction plates, teeth and general servicing of the equipment. The glass absorption columns were provided as... Continue Reading
    ABSTRACT A table top liquid-liquid extraction unit was constructed.  The project also involved the repair and servicing of peristaltic suction pump, by painting it, replacing the connecting cord to the power supply, refilling of the work out suction plates, teeth and general servicing of the equipment.  The glass absorption columns were provided... Continue Reading
    Call Us
    whatsappWhatsApp Us