ABSTRACT


Fiber optic communication systems have revolutionized the telecommunications industry, because it is used for faster transmitting of telephone signals, internet communication and cable television signal due to such lower attenuation and interference. The optical fibers are buried deep in the ground (1.2-1.5 meters) away from human activities. However, these fibers are been cut on frequently, the minute a fiber is cut, there is a halt in the smooth transition of signal.

 To prevent this occurrence, we designed and constructed underground cable cut detection system. The underground monitoring system comprises of two parts, the Fm transmitter and distance to fault measurement system. FM transmitter was design to broadcasts radio signals of frequency 73.4 MHz with the aid of a trimmer accompanied by an antenna. An interrupt signal was generated when there is a cut on power cable joining the transmitter circuit and the power supply. To find the exact position where an intruder is working we employed the distance to fault measurement system. Resistors where fixed parallel across a copper wire at an interval of 1m at a distance of 10m and the total resistor value was measured with a fixed multimeter. A cut on the wire indicated a change in the resistor value on the multimeter reading and hence the distance was figured from the distance to fault document drafted. This project was designed to provide a quick respond system to the network operator of intruders attempting to destroy underground fiber cables during signal transmission.

TABLE OF CONTENT

 

DEDICATION ___________________________________________ I

ACKNOWLEDGEMENT___________________________________V

ABSTRACT ___________________________________________________________ vi

CHAPTER ONE ________________________________________________________ 1

INTRODUCTION _______________________________________________________ 1

1.1PROBLEM STATEMENT___________________ 4

1.2 AIMS/ OBJECTIVES ____________________________________________ 4

1.3 SCOPE AND LIMITATIONS4

CHAPTER TWO ________________________________________________________ 6

THEORY______________________________________________________________ 6

2.1 UNDERGROUND MONITORY SYSTEM_________________________6

2.1.1 FM TRANSMITTER______________________________________ 6

2.1.1.1 PRE-AMPLIFIER_______________________________________ 7

2.1.1.2 LC OSCILLATOR______________________________ 8

2.1.1.3 FMMODULATOR__________________________10

2.1.2 LAID CABLES SYSTEM_________________________________________________ 11

2.1.2.1 MONITORY CABLE SYSTEM______________________________12

2.1.2.2 RESISTORS MULTIMETER CABLE_________________________12

2.1.3 RECEIVING UNIT ________________________________________13

2.2 OUTPUT SIGNAL_____________________________________14

2.2.1 ELECTROMAGNETIC WAVE

2.2.2 RADIOWAVE

2.2.3 FREQUENCY MODULATION

CHAPTER THREE _____________________________________________________15

METHODOLOGY______________________________________________________15

3.1 INTRODUCTION__________________________________________15

3.2 PLANNING_________________________________________________ 15

3.2.1 DATA COLLECTION______________________________________________________ 15

3.3 IMPLEMENTING___________________________________ 17

3.3.1CONSTRUCTION________________________________________________________ 20

3.3.2 CHECKING_____________________________ 22

3.4 ANALYSIS________________________22

3.4.2 CIRCUIT DESCRIPTION _____________________________________________ 22

3.5 APPLICATIONS________________________________________________ 24 viii

3.5.1 FM TRANSMITTER________________________27

3.5.2 DISTANCE TO FAULT                                                       

CHAPTER FOUR ______________________________________________________ 30

RESULTS AND DISCUSSION ___________________________________________ 30

4.1 DISTANCE TO FAULT DOCUMENT _______________________30

4.1.1 RESISTANCES AND LENGTH READINGS _______ _______ 33

4.4 SYSTEM TEST RESULTS AND ERRORS________________________ 35

CHAPTER FIVE _______________________________________________________36

CONCLUSION AND RECOMMENDATION ________________________________36

5.1 CONCLUSION ___________________________________________ 36

5.2 RECOMMENDATIONS _____________________________________ 36

REFERENCES ________________________________________________________ 38

APPENDIX ___________________________________________________________ 40

APPENDIX A ______________________________________________ 40           

RESISTOR MULTIMETER CABLE SYSTEM _____________________40

APPENDIX B _______________________________________________45          

SPEED OF ELECTROMAGNETIC WAVE DERIVATION________________________45

APPENDIX C _______________________________________________49

WAVELENGTH- FREQUENCY RELATION FORMULAR DERIVATION_______ 49

APPENDIX D _______________________________________________49

HARDWARE REQUIREMENT _______ 50



HOW TO PREVENT UNDERGROUND FIBER CABLE CUT
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Mass Communication
  • Project ID: MAS1775
  • Access Fee: ₦5,000 ($14)
  • Pages: 47 Pages
  • Format: Microsoft Word
  • Views: 532
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Mass Communication
    Project ID MAS1775
    Fee ₦5,000 ($14)
    No of Pages 47 Pages
    Format Microsoft Word

    Related Works

    Abstract Western states like US, France, UK, etc are technological developed particularly in television and motion programmes  this made them dominate other developing nations which include Nigeria as a a result  Nigerians portray  Western cultures and values cultivated  through the media. On this thrust that the research examine the influence... Continue Reading
    PRODUCT DEVELOPMENT IN THE CABLE INDUSTRY: PROBLEMS AND PROSPECT. (A CASE STUDY OF CUTIX CABLE PLC NNEWI ANAMBRA STATE ) CHAPTER ONE INTRODUCTION: The product or watchword for marketing has to be associated to “innovation or die. This innovational attributes can become a philosophy compelling or almost parallel to that of the marketing concept... Continue Reading
    ABSTRACT In our present society, communication is more or less the “cannot – do – without” that people always say and the strength of every successful business generally. The impact of this can be felt in the life of individuals, homes and government establishment, without adequate communication network every activity is useless... Continue Reading
    ABSTRACT In our present society, communication is more or less the “cannot – do – without” that people always say and the strength of every successful business generally. The impact of this can be felt in the life of individuals, homes and government establishment, without adequate communication network every activity is useless... Continue Reading
    CONSTRUCTION OF AUTOMATIC WATER LEVEL CONTROLLER FOR BOTH OVERHEAD AND UNDERGROUND TANKS ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When... Continue Reading
    ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized.... Continue Reading
    ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized.... Continue Reading
    ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized.... Continue Reading
    ABSTRACT Automatic water level controller for both overhead and underground tank is designed to monitor the level of water in a tank. It displays the level of water and when it is at the lowest level; a pump is activated automatically to refill the tank. When the tank is filled to its maximum capacity, the pump is automatically de-energized.... Continue Reading
    ABSTRACT Alaago-Alapoti area constitutes part of the Eestern Dahomey Basin of South-Western Nigeria and it is characterized by different formations. Samples were collected from this area and were subjected to the laboratory for test. Nine smaples were collected from Alaago-Alapo area, five hand-dug wells and four boreholes sampled and investigated... Continue Reading
    Call Us
    whatsappWhatsApp Us