COMPARATIVE ANALYSIS OF MICROBIAL LOAD OF THE ENUGU MAIN WATER PRODUCTION AND WATER AVAILABLE TO IMT CAMPUS II HOSTEL

  • Type: Project
  • Department: Microbiology
  • Project ID: MCB0152
  • Access Fee: ₦5,000 ($14)
  • Pages: 47 Pages
  • Format: Microsoft Word
  • Views: 985
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853
ABSTRACT

Samples of water from the different hostels in campus II and other source of water production namely Ajali-owa water, from bore hole 9th mile and spring water from GRA water board were water collecterd and analysed using total plate count and multiple tube fermentaton techniques coliform.  The results shows no coliforms in production water from Ajali-owa and in GRA spring water reservaiour and no coliform in 9th mile bore hole water, 14 organism and 149 cfu/ml plate counts were obtained from tap water in IMT campus II hostel 7 coliform and Tocful / ml plate count from well water and 28 coliform and 280 cfu/ml plate count from spillage waste water.  These results obtained show that tap water  consumed in IMT campus II did not meet with NAFDAC and WHO standards.  Preventive measures such as proper treatment of these water should be encourage and all pipes in campus II should be checked for leakages

TABLE OF CONTENT
Title page
Certification
Dedication
Acknowledgement
Abstract
Table of content
CHAPTER ONE
1.0   Introduction
1.1   Aims / objectives of the study
1.2   Statement of problems
1.3   Hypothesis
1.4   Scope of limitation

CHAPTER TWO
Literature review
2.1   The major group of biological Pollutions of water
2.2   Source of water supply
2.3   Source of water pollution
2.4   Treatment of water sample
2.5   International standard for drinking water
2.6   Diseases from water

CHAPTER THREE
3.0   Materials & methods
3.0   Materials
3.1   Media preparation
3.2   Collection of samples
3.3   Collection of samples
3.4   Methods of water analysis
3.5   Determination of PH
3.5.1 Determination of bacteria of the coliform
3.5.2 Culture techniques
3.5.3 Plate count technique
3.5.4 Presumption coliform (multiple tube fermebtation
3.5.4 Confirmatory test
3.5.5 Completed test
3.5.6 Test for indole
3.5.7 Methyl red test
3.5.8 Sugar test
3.5.9 Oxidase test
3.5.10Catakase test
3.5.11The slide cougulase test
3.5.12Gram stain techniques
3.5.13Detection of faecal stredtococci
3.5.14Detection of escherichi coli test
3.5.15Organism suspected after gram staining

CHAPTER FOUR
RESULTS

CHAPTER FIVE
Discussion

CHAPTER SIX
6.1   Conclusion 
6.2   Recommendation
      References
      Appendix

COMPARATIVE ANALYSIS OF MICROBIAL LOAD OF THE ENUGU MAIN WATER PRODUCTION AND WATER AVAILABLE TO IMT CAMPUS II HOSTEL
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Microbiology
  • Project ID: MCB0152
  • Access Fee: ₦5,000 ($14)
  • Pages: 47 Pages
  • Format: Microsoft Word
  • Views: 985
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Microbiology
    Project ID MCB0152
    Fee ₦5,000 ($14)
    No of Pages 47 Pages
    Format Microsoft Word

    Related Works

    ABSTRACT             Samples of water from the different hostels in campus II and other source of water production namely Ajali-owa water, from bore hole 9th mile and spring water from GRA water board were water collecterd and analysed using total plate count and multiple tube fermentaton techniques coliform.  The results shows no... Continue Reading
    ABSTRACT Samples of water from the different hostels in campus II and other source of water production namely Ajali-owa water, from bore hole 9th mile and spring water from GRA water board were water collected and analyzed using total plate count and multiple tube fermentation techniques coliform. The results shows no coliforms in production water... Continue Reading
    TO IMT CAMPUS II HOSTEL ABSTRACT Samples of water from the different hostels in campus II and other source of water production namely Ajali-owa water, from bore hole 9th mile and spring water from GRA water board were water collected and analyzed using... Continue Reading
    (EMENE LOCALITY) ABSTRACT Comparative analysis  of water was  carried out on well water, stream and pipe born water obviated within Emene locality of Enugu state the sample were subjected to some analytical tests final like presumptive tests, comfirmative... Continue Reading
    ABSTRACT Comparative analysis  of water was  carried out on well water, stream and pipe born water obviated within Emene locality of Enugu state the sample were subjected to some analytical tests final like presumptive tests, comfirmative test final like presumptive tests, comfirmative test, completed test, indole test and plate count for the... Continue Reading
    ABSTRACT Comparative analysis of water was carried out on well water, stream and pipe born water obviated within Emene locality of Enugu state the sample were subjected to some analytical tests final like presumptive tests, comfirmative test... Continue Reading
    ABSTRACT Comparative examination of three main sources of water supply in Independence layout Enugu was carried out with a view to determine their levels of contamination of bacteria. The sources of water examined are tap water, well water and stream water. The pour plate method was used to examine the water samples. Bacteria isolated from the... Continue Reading
    ABSTRACT Comparative analysis of water was carried out on well water, stream and pipe born water obviated within Emene locality of Enugu state the sample were subjected to some analytical tests final like presumptive tests, comfirmative test... Continue Reading
    ABSTRACT Comparative examination of three main sources of water supply in Independence layout Enugu was carried out with a view to determine their levels of contamination of bacteria. The sources of water examined are tap water, well water and stream water. The pour plate method was used to examine the water samples. Bacteria isolated from the... Continue Reading
    TABLE OF CONTENTS Title page ..............................................................................................i Certification page...................................................................................ii Dedication............................................................................................iii... Continue Reading
    Call Us
    whatsappWhatsApp Us