ABSTRACT
Buildings are supposed to shield their occupant from the solar radiation which especially in the hot dry climate of Bauchi pose problems of high indoor temperatures, thermal and visual discomfort among others. But to what extent does the Architectural solar control measures viz; shading, building orientation with respect to cardinal direction, and design or planning affect cooling? The current study investigates effect of exploiting these strategies on passive solar control in institutional buildings in ATBU with the aim of enhancing passive solar control on human thermal comfort. The study is a Case Study research of the main university library building in ATBU Bauchi Yelwa campus, from which physical observation were made; oriented to N/S and E/W, with three courtyards within the building, without vegetation in the courtyards. The passive solar control strategies and techniques used in the building to achieve human thermal comfort were investigated. The results showed that the building has achieved most of the strategies required in controlling heat gain. Hence, the study recommended for retrofitting by insulating external wall and roof, increase sizes of window openings, vegetating the courtyards, landscaping the immediate environment etc.

TABLE OF CONTENT
Title page……………………………………………………………………………………………….i
Declaration…………………………………………………………………………………………….ii
Certification………………………………………………………………………………………….iii
Dedication…………………………………………………………………………………………….iv
Acknowledgement.………………………………………………………………………………..v
Abstract………………………………………………………………………………………………..vi
Table of contents…………………………………………………………………………………vii

CHAPTER ONE: INTRODUCTION
1.0 Introduction…………………………………………………………………………………...1
1.1 Background of the study…………………………………………………………………2
1.2 Statement of the problem………………………………………………………………4
1.3 Aim and Objectives…………………………………………………………………………5
1.4 Research Questions………………………………………….……………………………..6
1.5 Significance Of the Study………………………………….……………………………..6
1.6 Operational Definition Of Terms…………………….……………………………….7

CHAPTER TWO: LITERATURE REVIEW
2.0 Introduction………………….……………………………………………………………….10
2.1 passive cooling……………………………………..………………………………………..10
2.1.1 Strategies Of Passive Cooling…………………………………..………………….11
2.2 Thermal Comfort………………………………..………………………………………….15
2.2.1 Sources of Heat That Causes Discomfort In The Enclosed Environment ……………16
2.2.2 Thermal Comfort In Building Design……………………………………………16
2.3 Factors Influencing Thermal Comfort In Buildings……………..…………..17
2.3.1 Climatic Factors………………………………………..………………………………….18
2.3.2 Human Factors………………………………………………..………………………….18
2.4 Thermal Performance and Choice Of Building Materials In Hot Dry Zone………………..19
2.5 Solar Control……………………………………………………………………..…………..22
2.5.1 Solar Control And Heat Protection…………………………………..………….22
2.5.2 Thermal Properties Of Building Elements……………………………..…….22
2.5.3 Building Orientation As A Tool Of Solar Control……………………..……23
2.5.4  Building Shape And Volume As An Element Of Solar Control………27
2.5.5 Shading As A Strategy Of Solar Control…………………………..……………29
2.6 Design For Hot-Arid Zones……………………………………………………..………44
2.6.1 Design For Hot-Humid Zones……………………………………………………….46
2.7 Thermal Mass…………………………………………………………………………………48
2.7.1 Properties Of Thermal Mass………………………………………………………..48
2.8 Heat Dissipation……………………………………………………………..……………..52
2.8.1 Design Problem And Challenges………………………………………………....53
2.8.2 Design Guiding Principles…………………………………………………………….54
2.9  Theories Of The Effects Of Passive Solar Control On Energy Use In Buildings…..……….56


CHAPTER THREE: RESEARCH METHODOLOGY
3.0 Research Methodology………………………………………………………………..59
3.1 Introduction…………………………………………………………………………………59
3.2 Sources Of Data……………………………………………………………………………..59
3.2.1 Primary Data……………………………………………………………………………….60
3.2.2 Secondary Data..………………………………………………………………………….61
3.3 Data Analysis………………………………………………………………………………….61
3.4 Study Area……………………………………………………………………………………..61
3.4.1 Background of The Study Area…………………………………………………….61
3.4.2 Existing Development………………………………………………………………….63
3.4.3 Case Study………………………………………………………………………………….63
3.5 Climate And Geography…………………………………………………………………65
3.5.1 Local Climatic Data………………………………………………………………………65
3.5.2 Wind……………………………………………………………………………………………66
3.5.3 Rainfall………………………………………………………………………………………..66
3.5.4 Temperature And Humidity………………………………………………………..67
3.5.5 Evaporation…………………………………………………………………………………68
3.6 Geography…………………………………………………………………………………….68
3.6.1 Geology………………………………………………………………………………………69
3.6.2 Vegetation………………………………………………………………………………….69


CHAPTER FOUR: DATA PRESENTATION AND ANALYSIS
4.0 Introduction…………………………………………………………………………………..70
4.1 Presentation And Analysis Of Data From The Research Questions ……………………....70
4.1.1 The Extent To Which Orientation Of The Building Affects Air Admissibility With Respect To The Cardinal Directions ……………………70
4.1.2 The Extent To Which Heat Is Gained Into The Building With Respect To The Orientation Of The Building ……………………………………………71
4.1.3 The Effect Vegetation Has On The Cooling Effect Of The Courtyards And The Building’s Interior ………………………..71
4.1.4 The Extent To Which Solar Control Strategies Reduces Heat Gain Into The Interior Space ……………………………………72
4.2 Presentation Of Results From The Physical Observations …………….72
4.2.1 Total Area Of The Building ……………………………..72
4.2.2 Total Area Of The Courtyards Within The Building ………………………73
4.2.3 Total Number Of Reading Sections In The Building ………………………73
4.2.4 Floor To Ceiling Height ……………………..74
4.2.5 Walling System And The Materials Used ……………………….74
4.2.6 Floor And Ceiling Materials Used ……………………………………74
4.2.7 Window Types, Size And Materials Used …………………………….74
4.2.8 Type Of The Shading Control Strategies Used ………………………..75

CHAPTER FIVE: SUMMARY, CONCLUSION AND RECOMMENDATION
5.0 Summary, Conclusion And Recommendations ………………………….76
5.1 General Review Of Work ……………………………………………………….76
5.2 Conclusion ………………………………………..77
5.3 Recommendation ………………………………………………….78

References …………………………………………………….80
THE EFFECTS OF PASSIVE SOLAR CONTROL ON HUMAN THERMAL COMFORT
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Architecture
  • Project ID: ARH0050
  • Access Fee: ₦5,000 ($14)
  • Pages: 76 Pages
  • Format: Microsoft Word
  • Views: 664
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Architecture
    Project ID ARH0050
    Fee ₦5,000 ($14)
    No of Pages 76 Pages
    Format Microsoft Word

    Related Works

    ABSTRACT This work investigated the variation of top loss heat transfer coefficient with the emittance of the absorber plate, the collector tilt angle and air gap spacing between the absorber plate and the cover plate. The effects of the emittance of the absorber plate, the collector tilt angle and air gap spacing between the plate and the cover... Continue Reading
    ABSTRACT This work investigated the variation of top loss heat transfer coefficient with the emittance of the absorber plate, the collector tilt angle and air gap spacing between the absorber plate and the cover plate. The effects of the emittance of the absorber plate, the collector tilt angle and air gap spacing between the plate and the cover... Continue Reading
    ABSTRACT Solar energy being transmitted from the sun through space to earth by electromagnetic radiation must be converted to heat before it can be used in a practical heating or cooling system. Solar energy collectors, the devices used to convert the suns radiation to... Continue Reading
    ABSTRACT Solar energy being transmitted from the sun through space to earth by electromagnetic radiation must be converted to heat before it can be used in a practical heating or cooling system. Solar energy collectors, the devices used to convert the suns radiation to heat, usually consist of a surface that efficiently absorbs radiation and... Continue Reading
    ABSTRACT  Energy and exergy analysis of solar air heater with phase change material energy storage is considered in this research work. Energy and exergy models for component systems like flat plate solar collector and phase change material in one-dimensional heat conduction in a cylindrical pipe, for storing periods were obtained. Exergy... Continue Reading
    ABSTRACT Buildings supposed to shield their occupant from the perturbing solar radiation which especially in the hot dry climate of Yola pose problems of high indoor temperatures, thermal and visual discomfort among others. But to what extend does the Architectural solar control measures viz; shading, building orientation with respect to cardinal... Continue Reading
    ABSTRACT Buildings supposed to shield their occupant from the perturbing solar radiation which especially in the hot dry climate of Yola pose problems of high indoor temperatures, thermal and visual discomfort among others. But to what extend does the Architectural solar control measures viz; shading, building orientation with respect to cardinal... Continue Reading
    Abstract The research was conducted on the topic “Assessment Of The Thermal And Non-Thermal Impact Of Ultrasound, A Case Study Of Ahmadu Bello University Teaching Hospital, Shika Zaria”. Ultrasound sonography is an imaging technique of generating images using a very high frequency sound wave. Sound is a mechanical, vibration form of energy.... Continue Reading
    CHAPTER ONE INTRODUCTION 1.1 Background Information Electricity is a general term comprising of a variety of phenomena resulting from the presence and flow of electric charge. These include many phenomena, such as lightning,... Continue Reading
    CHAPTER ONE INTRODUCTION 1.1Background Information Electricity is a general term comprising of a variety of phenomena resulting from the presence and flow of electric charge. These include many phenomena, such as lightning, static... Continue Reading
    Call Us