EXERGETIC EFFICIENCY OF PASSIVE SOLAR AIR HEATER WITH PHASE CHANGE ENERGY STORAGE MATERIAL

  • Type: Project
  • Department: Mechanical Engineering
  • Project ID: MCE0249
  • Access Fee: ₦5,000 ($14)
  • Pages: 90 Pages
  • Format: Microsoft Word
  • Views: 444
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

ABSTRACT 

Energy and exergy analysis of solar air heater with phase change material energy storage is considered in this research work. Energy and exergy models for component systems like flat plate solar collector and phase change material in one-dimensional heat conduction in a cylindrical pipe, for storing periods were obtained. Exergy analysis, which is based on the second law of thermodynamics, and energy analysis, which is based on first law, was applied to improve system efficiency. Measured data, like hourly insolation, collector temperature, PCM temperature, environmental temperature and air flow rate were used as an input on the energy and exergy models to determine system performance. The Software, Engineering Equation Solver (EES) was used to solve the generated equation models. The results of the analysis revealed that the average energy and exergy efficiencies were 48% and 35% respectively.


TABLE OF CONTENTS

Abstract - - - - - - - - - - i

Table of Contents - - - - - - - - - ii

Nomenclature - - - - - - - - - - iii

CHAPTER ONE

1. Introduction - - - - - - - - - 1

1.1 Objectives of Research - - - - - - - 3

CHAPTER TWO

2. Literature Review - - - - - - - - 4

2.2 Solar radiation- - - - - - - - - 8

2.3 The behavior of phase change material for charging periods- - - 13

CHAPTER THREE

3. The Energy analysis of the Absorber Plate - - - - - 15

3.1 The Exergy equation of the solar collector - - - - - 19

3.2 The Phase change material - - - - - - - 23

3.3 The Energy Balance Equation of PCM in cylindrical pipe for storing period 24

3.4 The Exergy Balance Equation of PCM - - - - - 26

CHAPTER FOUR

4. Results and Discussion - - - - - - - 29

CHAPTER FIVE

5. Conclusions - - - - - - - - - 61

 References - - - - - - - - - 62

Appendix A Computer program of the equation models - - 65

Appendix B Tables that show the results of the equation models - - 67

EXERGETIC EFFICIENCY OF PASSIVE SOLAR AIR HEATER WITH PHASE CHANGE ENERGY STORAGE MATERIAL
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Mechanical Engineering
  • Project ID: MCE0249
  • Access Fee: ₦5,000 ($14)
  • Pages: 90 Pages
  • Format: Microsoft Word
  • Views: 444
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Mechanical Engineering
    Project ID MCE0249
    Fee ₦5,000 ($14)
    No of Pages 90 Pages
    Format Microsoft Word

    Related Works

    ABSTRACT Solar energy being transmitted from the sun through space to earth by electromagnetic radiation must be converted to heat before it can be used in a practical heating or cooling system. Solar energy collectors, the devices used to convert the suns radiation to... Continue Reading
    ABSTRACT Solar energy being transmitted from the sun through space to earth by electromagnetic radiation must be converted to heat before it can be used in a practical heating or cooling system. Solar energy collectors, the devices used to convert the suns radiation to heat, usually consist of a surface that efficiently absorbs radiation and... Continue Reading
    INTRODUCTION The primary objective of the store function is to provide service to the operating functions and these services cannot be provided without proper provision of storage facilities. The impact of storage facilities on store efficiency is to ensure that goods regularly required are stored accordingly. Adequate care of materials held... Continue Reading
           CHAPTER I: Introduction The primary objective of the store function is to provide service to the operating functions and these services cannot be provided without proper provision of storage facilities.             The impact of storage facilities on store efficiency... Continue Reading
    INTRODUCTION The primary objective of the store function is to provide service to the operating functions and these services cannot be provided without proper provision of storage facilities. The impact of storage facilities on store efficiency is to ensure that goods regularly required are stored accordingly. Adequate care of materials held... Continue Reading
    Abstract This project work centered on construction of 12V/10A solar charge controller that is needed in photovoltaic system to safely charge regulate and discharge of sealed lead acid battery through DC load. Solar charge controller is devices that regulate solar photovoltaic power and prevent overcharging, over discharging or overflow of current... Continue Reading
    Abstract This project work centered on construction of 12V/10A solar charge controller that is needed in photovoltaic system to safely charge regulate and discharge of sealed lead acid battery through DC load. Solar charge controller is devices that regulate solar photovoltaic power and prevent overcharging, over discharging or overflow of current... Continue Reading
    ABSTRACT Buildings are supposed to shield their occupant from the solar radiation which especially in the hot dry climate of Bauchi pose problems of high indoor temperatures, thermal and visual discomfort among others. But to what extent does the Architectural solar control measures viz; shading, building orientation with respect to cardinal... Continue Reading
    ABSTRACT Buildings are supposed to shield their occupant from the solar radiation which especially in the hot dry climate of Bauchi pose problems of high indoor temperatures, thermal and visual discomfort among others. But to what extent does the Architectural solar control measures viz; shading, building orientation with respect to cardinal... Continue Reading
    ABSTRACT This work investigated the variation of top loss heat transfer coefficient with the emittance of the absorber plate, the collector tilt angle and air gap spacing between the absorber plate and the cover plate. The effects of the emittance of the absorber plate, the collector tilt angle and air gap spacing between the plate and the cover... Continue Reading
    Call Us
    whatsappWhatsApp Us