Abstract

This thesis aims to extract d-axis machine parameters of a 214 MVA high-speed turbogenerator using well-established offline techniques. MATLAB/SIMULINK tool has been utilized to model the generator and perform sudden short-circuit (SSC) tests. Because constant speed operation of the generator is vital consideration for the accuracy of SSC tests for parameter extraction, this thesis has employed an arrangement of 2 DC motors operating alongside a drive system, which is configured to couple the combined motor to drive the shaft of the generator to maintain synchronous speed throughout the test. Simulating the different drive configurations, the SSC oscillographs were captured and transformed into symmetrical envelope waveforms which were then used to extract the operational impedances and time constants of the generator. From the simulation tests, the influence of speed departures on shaft torques and current waveforms were presented and analysed. The results obtained for the variable-speed simulation using the drive system were then validated with those calculated from standard equations, as well as those of the constant-speed mode. The test results confirm that SSC tests can be performed on synchronous machines under rated conditions if the couplings can be appropriately designed to contain the dangerous values of electromagnetic torque that are developed during such tests. In addition, an electronic switch was designed to manage the abnormal field current which results from the introduction of SSC currents. In the end, the switching contraption is seen to reduce the power losses in the machine’s field winding during SSC. 

MODELING MODELINGAND PARAMETER EXTRACTION OF A AND PARAMETER EXTRACTION OF A 214 MVA TURBO- 214 MVA TURBO-GENERATOR DRIVEN BY DC GENERATOR DRIVEN BY DC MOTORS DURING OFF- MOTORS DURING OFF-LI
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Electrical Engineering
  • Project ID: ELE0513
  • Access Fee: ₦5,000 ($14)
  • Pages: 96 Pages
  • Format: Microsoft Word
  • Views: 603
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Electrical Engineering
    Project ID ELE0513
    Fee ₦5,000 ($14)
    No of Pages 96 Pages
    Format Microsoft Word

    Related Works

    Abstract This thesis aims to extract d-axis machine parameters of a 214 MVA high-speed turbogenerator using well-established offline techniques. MATLAB/SIMULINK tool has been utilized to model the generator and perform sudden short-circuit (SSC) tests. Because constant speed operation of the generator is vital consideration for the accuracy of SSC... Continue Reading
    ABTRACT Hematological parameters are measurable indices of the blood that serve as a marker for disease diagnosis. The aim of this study was to evaluate hematological parameters of patients with malaria in Nigeria. This was a prospective study in which the... Continue Reading
    ABSTRACT The horticulture industry sustains millions of livelihoods in Kenya through local and export markets.The study sought to assess the economic efficiency of tomato production with a view to initiating appropriate interventions, including informing tomato development initiatives and policy makers. The research took a broad use of survey... Continue Reading
    ABSTRACT Drug abuse affects an individual in any organization by directly affecting their health rendering them less productive and inefficient. In the long run the organization fails to achieve their objective as a result of unproductive workers, high absenteeism, shoddy work and reduced staff morale. This study aimed at assessing the extent... Continue Reading
    For many years, procurement has been advancing day by day due to technology changes .the manual system of direct buying and selling is being sized out slowly with the improvement in technology “electronic procurement” coming on board in the procurement sector Karehka (2008) explains Electronic procurement as the business to business purchase... Continue Reading
    ABSTRACT The purpose of the study was to establish or investigate the relationship between inventory management and customer satisfaction in Spear Mctors Limited Kampala basing on the following objectives, to examine inventory management techniques used in organization, to find out the factors affect customer satisfaction in organizations, to... Continue Reading
    CHAPTER ONE 1.1    INTRODUCTION 1.2    Both the private and government sectors nowadays lay emphasis on strategic planning, balancing of records control and rapid response to a development problems. The result is a constant demand for better and more timely information. The need for efficient planning and controlling cannot be over-emphasized.... Continue Reading
    DESIGN AND MANUFACTURE OF A FUEL-LESS GENERATOR ABSTRACT The fuel-less generator is a flywheel energy storage system (FESS) which has attracted new research attention recently in applications like power quality, regenerative braking and uninterruptible power supply (UPS). As a sustainable energy storage method, flywheel energy storage has become a... Continue Reading
    Abstract In this work, a 2.8kva alternator was coupled to a 4 H.P dc motor acting as a prime mover to produce a fuel-less generator. The coupling was done using two crankshaft pulleys to match the speed of the alternator to that of the dc motor. Two 24v dc deep cycle batteries were also used as the exciter unit and a sustainable output voltage of... Continue Reading
    Abstract In this work, a 2.8kva alternator was coupled to a 4 H.P dc motor acting as a prime mover to produce a fuel-less generator. The coupling was done using two crankshaft pulleys to match the speed of the alternator to that of the dc motor. Two 24v dc deep cycle batteries were also used as the exciter unit and a sustainable output voltage of... Continue Reading
    Call Us
    whatsappWhatsApp Us