CALIBRATION AND APPLICATION OF CATHODE RAY OSCILLOSCOPE IN OUR LABORATORY

  • Type: Project
  • Department: Science Lab Technology
  • Project ID: SLT0139
  • Access Fee: ₦5,000 ($14)
  • Pages: 39 Pages
  • Format: Microsoft Word
  • Views: 1.2K
  • Report This work

For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853
ABSTRACT 
The cathode ray Oscilloscope plays a very important role in the laboratories, for instance it is used to measure frequency and voltage of a signal it is equally used for study current fluctuation in electric power supply the cathode ray oscilloscope is made up of three major part, they are the cathode ray tube, which is the major integral part A the Oscilloscope also the other important[1 parts of the Oscilloscope is the power supply unit and the vertical as well as horizontal amplifier. Some of the cathode ray oscillioscope are calibrated manually while some are already calibrated by the manufacturers.  The subpart of the oscilloscope which include Cathode Ray Tube   (CRT) is made of three (3) major parts namely the electron gun which produces electron before acceleration and the second sub part of the instrument in the deflecting plates which helps to deflect the electron towards the screen where it is seen.  This cathode Ray Oscilloscope works in the principle that the signal to be displayed is amplified by the vertical amplifier and applied to the vertical deflection plates of the CRT, a portion of the signal in the vertical amplifier is applied to the sweep trigger as a triggering signal.  Then the sweep trigger generates a pulse coincident with a selected point in the cycle of the triggering signal.  This pulse turns on the sweep generator. Initiating the saw-tooth wave form.

TITLE PAGE 
Title Page i
Certification ii
Dedication iii
Acknowledge iv
Abstract. v
Table of Contents vi

CHAPTER ONE 
1.0 Introduction 1
1.1 The Background Review of the Cathode Ray Oscilloscope 1
1.2 Limitations of the Study 7
1.3 Objective of the study 8
1.4 Definition of Terms 8

CHAPTER TWO 
2.1 Mode of operation of Cathode Ray Oscilloscope 9
2.2 Scheme Diagram of CRO 10
2.3 The Parts of Cathode Ray Oscilloscope (CRO) 10
2.4 Schematic Diagram of Cathode Ray Tube 11
2.4.1 The pars of Cathode Ray (CRT) 12
2.4.2 Vertical Amplifier 13
2.4.3 Delay Line 14
2.4.4 The Power Supply Section 15
2.4.5 Time Base Generator 15
2.4.6 Horizontal Sweep Section 15

CHAPTER THREE 
3.0 Calibration and setting up of cathode Ray 
Oscillioscope 17
3.1 Setting of Cathode Ray Oscilloscope 17
3.2 The Summary for setting up CRO 23
3.3 Calibration of Cathode Ray Oscilloscope 24

CHAPTER FOUR 
4.0 Application of Cathode Ray Oscilloscope in
 Laboratory 25
4.1 CRO as a voltmeter 25
4.2 Frequency Measurement with CRO 29
4.3 Measurement of Voltage and Time Period 30


CHAPTER FIVE
5.0 Summary, Conclusion and Recommendation 32
5.1 Summary 32
5.2 Conclusion 33
5.3 Recommendation 34
REFERENCES 35


CALIBRATION AND APPLICATION OF CATHODE RAY OSCILLOSCOPE IN OUR LABORATORY
For more Info, call us on
+234 8130 686 500
or
+234 8093 423 853

Share This
  • Type: Project
  • Department: Science Lab Technology
  • Project ID: SLT0139
  • Access Fee: ₦5,000 ($14)
  • Pages: 39 Pages
  • Format: Microsoft Word
  • Views: 1.2K
Payment Instruction
Bank payment for Nigerians, Make a payment of ₦ 5,000 to

Bank GTBANK
gtbank
Account Name Obiaks Business Venture
Account Number 0211074565

Bitcoin: Make a payment of 0.0005 to

Bitcoin(Btc)

btc wallet
Copy to clipboard Copy text

500
Leave a comment...

    Details

    Type Project
    Department Science Lab Technology
    Project ID SLT0139
    Fee ₦5,000 ($14)
    No of Pages 39 Pages
    Format Microsoft Word

    Related Works

    ABSTRACT The Nigerian economy is filled with different kinds of services providing industries, ramping from the large ones like banks to very small ones such as hair saloon services. The deepering economic problems in the country has made services provision of all kinds very expensive and competitive. The only solution to survive is to engage... Continue Reading
    ABSTRACT   The Nigerian economy is filled with different kinds of services providing industries, ramping from the large ones like banks to very small ones such as hair saloon services. The deepering economic problems in the country has made services provision of all kinds very expensive and competitive. The only solution to survive is to engage... Continue Reading
    Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine  instrument constants and errors. A series of measurements on a base can also be used to check  the performance and reliability of the instrument over time and to assess its precision against  the manufacturer's specifications. This research work, the... Continue Reading
    Electromagnetic Distance Measurement (EDM) equipment is calibrated on a base to determine  instrument constants and errors. A series of measurements on a base can also be used to check  the performance and reliability of the instrument over time and to assess its precision against  the manufacturer's specifications. This research work, the... Continue Reading
    ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
    ABSTRACT A Linear  Variable Differential Transformer (LVDT) was constructed having a primary winding of 245 turns and two secondary windings of 100 turns each. The device was calibrated with a graduated cylindrical rod. The graduated rod when inserted between the hollow tube which has the windings gave output voltages of ±0.046V, ±0.51V,... Continue Reading
    Crude oil viscosity is an important parameter which is considered in both porous media and in pipeline channels. Estimating oil viscosity at various operating conditions of pressure and temperature is of great value to petroleum engineers. In petroleum and reservoir engineering, we are often faced with the analysis of processes which involve... Continue Reading
    Crude oil viscosity is an important parameter which is considered in both porous media and in pipeline channels. Estimating oil viscosity at various operating conditions of pressure and temperature is of great value to petroleum engineers. In petroleum and reservoir engineering, we are often faced with the analysis of processes which involve... Continue Reading
    ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at two different power levels: half power (15kW) and full power (30kW). The calorimetric method... Continue Reading
    ABSTRACT This research work presents the results of the thermal power calibration of Nigeria Research Reactor-1 (NIRR-1), a low power Miniature Neutron Source Reactor (MNSR), using calorimetric and heat balance methods. The calibration was performed at... Continue Reading
    Call Us
    whatsappWhatsApp Us